Key ASDP (Australian Synchrotron Development Proposals)
Chantler et al., Atomic plasma and laboratory astrophysics at a synchrotron
Joint proposal - Lay, Chantler, Ridgway for XAS development at the Australian Synchrotron
Each of these have wide community support and more is welcome. The first one is the first proposal involving the Australian physics community and links up to the plasma science, the atomic physics, the relativistic quantum theory and experimental, the laboratory astrophysical and general astrophysical communities, and signatories come from all these areas. The second is particularly developed for advanced high-performance XAS, including accuracies some 100 times that of the literature, including development and implementation of XERT, Hybrid, room temperature, cryogenic, transmission and fluorescence XAS of pure/ideal but also dilute/radiation sensitive samples, where dilute is defined as being down to 1 mM and likely less for full XAFS, and likely 0.1 mM for XANES; together with energy calibration and RIXS platform. Use of high-flux high-linearity detector technology will be assumed, and experimental uncertainties will be determined in pre-processing and propagated for hypothesis testing. Recently this has been coordinated into a Science Case for future Beamline support [2015].
2. C. T. Chantler, "Towards improved form factor tables", pp 61-78, Invited review chapter in Resonant Anomalous X-Ray Scattering. Theory and Applications, G. Materlik, K. Fischer, C.J. Sparks, eds, (Elsevier, North-Holland, 1994).
C. Q. Tran, C. T. Chantler, D. Paterson, "The physics of x-ray production by electron bombardment: new understanding and experiments," Proceedings of the European conference on Energy Dispersive X-ray Spectrometry, Eds J.E. Fernandez, A Tartari (Editrice Compositori, Bologna 1999) 45-51
19. C.T. Chantler, "Improvements in computation of form factors", Radiation Physics and Chemistry (International Journal of Radiation Applications and Instrumentation, Part C) (Invited) 41 (1993) 759-766.
25. J.D. Gillaspy, Y. Aglitskiy, E.W. Bell, C.M. Brown, C.T. Chantler, R.D. Deslattes, U. Feldman, L.T. Hudson, J.M. Laming, E.S. Meyer, C.A. Morgan, A.I. Pikin, J.R. Roberts, L.P. Ratliff, F.G. Serpa, J. Sugar, E. Takacs, "Overview of the EBIT Program at NIST," Physica Scripta, T59, 392-395 (1995).
26. C. T. Chantler, R. D. Deslattes,"Systematic Corrections in Bragg X-ray Diffraction of Flat and Curved Crystals", invited review paper in Rev.Sci.Inst. 66 (1995) 5123-5147.
58. C. T. Chantler, "Scattering factor calculations and dispersion corrections for heavy atoms," J. Physics and Chemistry of Solids 65 (2004) 1935-1941.
17. H. F. BEYER, K. D. FINLAYSON, D. LIESEN, P. INDELICATO, C. T. CHANTLER, R. D. DESLATTES, J. SCHWEPPE, F. BOSCH, M. JUNG, O. KLEPPER, W. KONIG, R. MOSHAMMER, K. BECKERT, H. EICKHOFF, B. FRANZKE, A. GRUBER, F. NOLDEN, P. SPADTKE, M. STECK, X-ray transitions associated with electron capture into bare dysprosium, J. Phys. B26 (1993) 1557-1567. [investigations of Radiative Electron Capture to test QED]
18. C. T. CHANTLER, Developments in computation of form factors, NIST SP850, eds J. Sugar, D. Leckrone (April 1993), pp23-25.
19. C. T. CHANTLER, Improvements in computation of form factors, Radiation Physics and Chemistry (Int. Journal of Radiation Applications and Instrumentation, Part C)(Invited) 41 (1993) 759-766.
25. J. D. GILLASPY, Y. AGLITSKIY, E. W. BELL, C. M. BROWN, C. T. CHANTLER, R. D. DESLATTES, U. FELDMAN, L. T. HUDSON, J. M. LAMING, E. S. MEYER, C. A. MORGAN, A. I. PIKIN, J. R. ROBERTS, L. P. RATLIFF, F. G. SERPA, J. SUGAR, E. TAKACS, Overview of the EBIT Program at NIST, Physica Scripta, T59, 392-395 (1995). [Nobel Symposium 1991, and first operation of the NIST EBIT]
27. C. T. CHANTLER, R. D. DESLATTES,Systematic Corrections in Bragg
X-ray Diffraction of Flat and Curved Crystals, Rev.Sci.Inst. 66 (1995) 5123-5147. [invited review article, many new results
for X-ray diffraction theory]
28. C. T. CHANTLER, J.-L. STAUDENMANN, Energy Dependences of Absorption in Beryllium Windows and Argon Gas, Rev. Sci. Inst. 66 (1995) 1651-1654.
32. C. T. CHANTLER, Erratum: Theoretical Form Factor, Attenuation and Scattering Tabulation for Z=1-92 from E=1-10 eV to E=0.4-1.0 MeV, J. Phys. Chem. Ref. Data 25 (1996) 527-532.
33. D. PATERSON, C.T. CHANTLER, C. TRAN, L. T. HUDSON, F. G. SERPA, R. D. DESLATTES, Absolute calibration of an x-ray spectrometer on the NIST electron-beam ion trap: control, design and systematics, Physica Scripta, T73 (1997) 400-402.
34. C. T. CHANTLER, D. PATERSON, L. T. HUDSON, F. G. SERPA, J. D. GILLASPY, R. D. DESLATTES, Progress towards absolute x-ray spectroscopy on the NIST electron-beam ion trap: current status and results, Physica Scripta, T73 (1997) 87-89.
35. C. T. CHANTLER, Resolution of Discrepancies of Atomic Form Factors and Attenuation Coefficients in the Near-edge soft X-ray regime, Rad. Phys. Chem. 55 (1999) 231-237.
38. C. T. CHANTLER, D. PATERSON, L. T. HUDSON, F. G. SERPA, J. D. GILLASPY, E. TAKACS Precision X-ray spectroscopy at the NIST Electron-Beam Ion Trap: resolution of major systematic error, Physica Scripta T80 (1999) 440-442
43. C. T. CHANTLER, C. Q. TRAN, D. PATERSON, Z. BARNEA, D. J. COOKSON, Direct Observation of Scattering Contribution in X-ray Attenuation
Measurement, and evidence for Rayleigh scattering from copper samples rather than thermal-diffuse or Bragg-Laue scattering, Rad. Phys. Chem. 61 (2001) 347-350.
45. C. T. CHANTLER, New Theoretical Investigation Resolving Discrepancies of Atomic Form Factors and Attenuation Coefficients in the Near-edge Soft X-ray Regime,
Rad. Phys. Chem. 61 (2001) 343-345.
47. C. T. CHANTLER, Detailed new tabulation of atomic form factors and attenuation coefficients in the near-edge soft X-ray regime (Z=30-36, Z=60-89, E=0.1 keV 8 keV),
addressing convergence issues of earlier work, J. Synch. Rad. 8 (2001) 1124 invited Letter to the Editor.
53. C. T. CHANTLER, Atomic form factor theory and experiment in the x-ray regime: A survey of progress and future
opportunities, invited review AOS News, 17 (2) June (2003) 9-16.
58. C. T. CHANTLER, Scattering factor calculations and dispersion corrections for heavy atoms,
J. Physics and Chemistry of Solids 65 (2004) 1935-1941.
62. M. D. DE JONGE, C. Q. TRAN, C. T. CHANTLER, Z. BARNEA,
Improved techniques for measuring x-ray mass attenuation coefficients, Proc. SPIE Vol. 5538,
p. 96-106, Optical Constants of Materials for UV to X-Ray Wavelengths; Regina Soufli, John F. Seely, Eds. (2004) IP
64. C. T. CHANTLER, Critical tests of higher-order and many-body Quantum Electrodynamics
(QED) theory in medium-Z and high-Z systems, invited review AOS News 19 (2005) 10-15
71. C. WITTE, C.T. CHANTLER, E.C. COSGRIFF, C.Q. TRAN,
Atomic cluster calculation of the X-ray near-edge absorption of copper,
Radiation Physics & Chemistry 75 (2006) 1582-1585 [Proof of concept for the Finite Difference Method for XANES in copper]
72. L. F. SMALE, C. T. CHANTLER, M. D. DE JONGE, Z. BARNEA, C.Q. TRAN,
Analysis of X-ray Absorption Fine Structure
using Absolute X-ray Mass Attenuation Coefficients: Application to Molybdenum,
Radiation Physics & Chemistry 75 (2006) 1559-1563
[Methodology explaining and resolving problems with standard XAFS analyses.]
73. N. A. RAE, C. T. CHANTLER, C. Q. TRAN, Z. BARNEA,
High-Precision Energy Determination of Synchrotron Radiation From Powder
Diffraction and Investigation of Profile Widths,
Radiation Physics & Chemistry 75 (2006) 2063-2066 [New technique for energy calibration.]
74. M. N. KINNANE, J. A. KIMPTON, C.T. CHANTLER,
A Status Report on Experimental Tests of QED in Medium-Z Systems, Radiation Physics &
Chemistry 75 (2006) 1744-1748 [Current stages of success in QED testing.]
75. J. A. KIMPTON, M. N. KINNANE, C. T. CHANTLER,
The development of a backgammon-type multi-wire proportional counter for the
detection of X-rays, Rev. Sci. Inst. 77 (2006) 08-3102-1-7. [Detector developments for high-precision research.]
76. M. D. DE JONGE, C. Q. TRAN, C. T. CHANTLER, Z. BARNEA, X-ray optics for the future: high-accuracy measurements of x-ray
mass attenuation coefficients, invited review and front cover, AOS News, 20 (2006), 30-37
77. J. D. BOURKE, C. T. CHANTLER, C. WITTE,
Finite Difference Method Calculations of X-ray Absorption Fine Structure for Copper,
Physics Letters A, 360 (2007), 702-706 [First demonstration that Finite Difference Method theory can be applied successfully in the XAFS regime.]
79. C. T. CHANTLER, N. A. RAE, C. Q. TRAN,
Accurate determination and correction of the lattice parameter of LaB6 (standard
reference material 660) relative to that of Si (640b), J. Appl. Cryst. 40 (2007) 232-240 [New technique for powder diffraction standards.]
82. J. L. GLOVER, C. T. CHANTLER,
The Analysis of X-ray Absorption Fine Structure: Beam-line independent interpretation,
Meas. Sci. Tech. 18 (2007) 2916-2920 [How XERT resolves major anomalies in current research.]
107. C. T. Chantler, L. T. Hudson, S. P. Best, Frontiers in Radiation Physics and Applications, Guest Editorial, NIM A619 (2010) vii
108. C. T. Chantler, L. T. Hudson, S. P. Best, Guest Editors, Frontiers in Radiation Physics and Applications, NIM A619, issues 1-3 (2010)
112: Kostorz, G., et al. [I. Ascone, C.T. Chantler], International Union of Crystallography Report of the Executive Committee for 2009, Acta Cryst. A67 (2011) 96-124
115. J. D. Bourke, C. T. Chantler,
Density functional calculations of electron energy loss data and inelastic mean free paths in elemental and binary materials
Acta Cryst A67 (2011) C170
116. N. A. Rae, C. T. Chantler,
The X-ray Extended Range Technique for high accuracy XAS for comparison and improvement to theoretical modeling
Acta Cryst A67, (2011) C582
117. C. T. Chantler, M. T. Islam, S. P. Best, F. Wang,
Ferrocene and Fluorescence Studies: How can we understand stereochemistry of dilute systems?
Acta Cryst A67 (2011) C516
118. C. T. Chantler, M. T. Islam, N. A. Rae, C. Q. Tran, J. L. Glover, Z. Barnea,
New consistency tests for high-accuracy measurements of x-ray mass attenuation coefficients by the X-ray extended range technique,
Acta Cryst. A68 (2012) 188-195 [absolute method for foils]
>> Physics Today December Issue!! SK Blau, Search and Discovery, Physics Today, Dec (2012), p22; http://www.physicstoday.org/daily_edition/physics_update/highly_charged_ions_challenge_qed
137. J. A. Lowe, C. T. Chantler, I. P. Grant
Ab initio determination of K a line strengths and energies in transition metal atoms,
J. Phys. CS 388 (2012) 032034
138. J. D. Bourke, C. T. Chantler,
Theoretical and experimental developments in the determination of electron energy loss functions and inelastic mean free paths in elemental solids and
binary compounds,
J. Phys. CS 388 (2012) 132008
139. C. T. Chantler,
The X-ray Extended Range Technique a model for investigating X-ray and electron collision processes at a synchrotron,
J. Phys. CS 388 (2012) 022040
140. C. T. Chantler,
Testing atomic and collision physics, QED, Plasma Physics, Laboratory Astrophysics and Fundamental Constants a visible, VUV, X-ray synchrotron source allied
with an Electron Beam Ion Trap,
J. Phys. CS 388 (2012) 082033
141. J. A. Lowe, C. T. Chantler, I. P. Grant,
Erratum to: "A new approach to relativistic multi-configuration quantum mechanics in titanium"
Phys. Lett. A377 (2013) 351-352 [Phys. Lett. A 374 (2010) 4756-4760]
>> http://iopscience.iop.org/0953-4075 citing C. T. Chantler, J. A. Lowe, I. P. Grant, J. Phys. B 46 (2012) 015002
146. C. T. Chantler, M. N. Kinnane, J. D. Gillaspy, L. T. Hudson, A. T. Payne, L. F. Smale, A. Henins, J. M. Pomeroy, J. A. Kimpton, E. Takacs,
K. Makonyi,
Reply to Comment on Testing Three-body Quantum Electrodynamics with trapped Ti20+ ions: Evidence for a Z-dependent divergence between experiment and calculation,
Phys. Rev. Letts 110 (2013) 159302-1-2
>>> Laboratory Highlight invited. A J Illig, C T Chantler, A T Payne, Determination of the 2p satellite profile through an improved characterization of copper K alpha, citing A J Illig, C T Chantler, A T Payne, Voigt Profile Characterisation of Copper K alpha, Journal of Physics B46 Sept (2013) 235001-1-11, http://m.iopscience.iop.org/0953-4075/labtalk-article/56166
1. C.T. Chantler, "Beam-foil Spectroscopy of highly-ionized atoms,
precision measurements of hydrogenic Lamb shifts and x-ray diffraction
of curved crystals", D.Phil. Thesis, Oxford, 1990. 14. C.T. Chantler, E.N. Maslen, "Charge Transfer and Three-Centre Bonding
in Monoprotonated and Diprotonated 2,2-Bipyridylium closo-Decaboron Hydride,"
Acta Cryst. B45 (1989), 290-297. 13. C.T. Chantler, J.D. Silver, "X-ray spectra of recoil ions from
fast beam interaction with Mg and MgF2 solid targets" (NIM B31 (1988)
59-69) and 12. J.M. Laming, C.T. Chantler, J.D. Silver, D.D. Dietrich, E.C. Finch,
P.H. Mokler and S.D. Rosner, "A Differential Measurement of the Ground
State Lamb Shift in Hydrogenic Germanium, Ge31+," NIM B31 (1988) 21-23
D1. NIST Database 66: FFAST - Form Factor Attenuation Scattering Tables
(Version 1.0) July 1995, C.T. Chantler. D2. NIST Database: FFAST II - Form Factor Attenuation Scattering Tables (Version 2.0)
Chantler, C.T., Olsen, K., Dragoset, R.A., Kishore, A.R., Kotochigova, S.A., and Zucker, D.S. (2003),
X-Ray Form Factor, Attenuation and Scattering Tables (version 2.0).
[Online] Available: http://physics.nist.gov/ffast
National Institute of Standards and Technology, Gaithersburg, MD. C. T. CHANTLER, Acta Cryst. A55 Supplement (1999) 531.
Z. BARNEA, C. Q. TRAN, C. T. CHANTLER, D. PATERSON, D. X. BALAIC, D. J. COOKSON, Acta Cryst. A55 Supplement (1999) 530-531.
C. Q. TRAN, C. T. CHANTLER, D. PATERSON, The physics of x-ray production by electron bombardment: new understanding and experiments,
Proceedings of the European conference on Energy Dispersive X-ray Spectrometry, Ed. J.E. Fernandez, A Tartari
(Editrice Compositori, Bologna 1999) 45-51
C. T. CHANTLER, The Hanbury Brown Ð Twiss Interferometer: A 46-year perspective, pp 198- 201,
Proceedings of the Australian Institute of Physics, 15th Biennial Congress, D. Neilson, ed. (8-11 July 2002, Sydney, ISBN 0-9598064-X,
2002, Australian Institute of Physics)
G. CHRISTODOULOU, C. T. CHANTLER, D. J. PATERSON, M. D. DE JONGE ,
Detector and Spectrometer Development for QED Measurements Using an EBIT,
pp313-316, Proceedings of the Australian Institute of Physics, 15th Biennial Congress,
D. Neilson, ed. (8-11 July 2002, Sydney, ISBN 0-9598064-X, 2002, Australian Institute of Physics)
M. N. KINNANE, C. T. CHANTLER, M. D. DE JONGE, A. G. PEELE, C. Q. TRAN, D. J. PATERSON, B. B. DHAL,
Upgrades to X-Ray Data Collection System ÐLeading to Absolute Measurements of Mass Attenuation Coefficients and Sub-Micron
Thickness Variation Detection at a Local Source, pp 317-319, Proceedings of the Australian Institute of Physics,
15th Biennial Congress, D. Neilson, ed. (8-11 July 2002, Sydney, ISBN 0-9598064-X, 2002, Australian Institute of Physics)
C. Q. TRAN, M. D. DE JONGE, Z. BARNEA, C. T. CHANTLER , X-Ray - Atom Interaction Cross-Sections: How Well Do We Know Them?,
Proc. 9th Asia-Pacific Physics Conference Oct (2004)
C. Q. TRAN, C. T. CHANTLER, M. D. DE JONGE, Z. BARNEA, N. RAE ,
The X-ray Extended Range Technique for high accuracy atomic structure in simple systems, AIP 16th National Congress Proc. (CD Rom) (2005) 91:1-3
C. T. CHANTLER, Databases for absorption, XAFS and XANES, and future opportunities for research and investigation,
Acta Cryst. A64 (2008) C626
R1 B.Sc. Honours Thesis "Electron density studies", UWA, Perth,
Western Australia (1984) R2 J.D. Silver, C.T. Chantler, "Final Report on Improved Crystal Bending
Techniques Applied to the LLNL Dual-Arm Johann mounting X-ray Spectrometer"
Re: LLNL # P.O. 2142003 (22/12/87). R3. C. T. Chantler, "Highlights from AOS 10, 5-7 July, 1995",
AOS News 9, Issue 3 (1995) 26 R4. G. Smith, C. Chantler, "Australian Optical Companies,"
AOS News 9, Issue 4 (1995), 37-48. R5. C.T. Chantler, P.M. Farrell, eds, "AOS99 Book of Abstracts,"
(AOS, July 1999, ISBN 0-7340-1737-5) R6: C. T. CHANTLER, Australian & New Zealand Physicist 35, 3 (1998) 131-132 (ISSN 1036-3831)
R7. C. T. Chantler, "Highlights from AOS99,",
AOS News 13, issue 2 (1999) 7-8. R8. C.T. Chantler, Highlights from AIP Congress 2000, AOS News 15, issue 1 (2001) 14-15. R9. C. T. Chantler, Atomic Form Factor Tables, Rare Earth Information Center News, 36 (2001) 1 R10. C. T. Chantler, AIP Congress Evaluation: Report from parallel sessions: AOS/AIP/ACOFT2002,
The Physicist 39 (2002) 145-146 R11: C. T. CHANTLER, The Physicist 40, 2 (Cambridge Scientific Minds, 2003) 52-53
R12: C. T. CHANTLER, other regular reviews in The Physicist e.g. 41 (4) July (Precision Physics of Simple Atomic Systems, 2004) 132
R13: C. T. CHANTLER, M. D. DE JONGE, C. Q. TRAN, Z. BARNEA, High-accuracy measurements of x-ray mass attenuation coefficients, IRPS Bulletin 21 (2007) 9-19.
R14: C. T. CHANTLER, Australian Physics 43 (2006, ISSN 1036-3831) 99-100
R15: C. T. CHANTLER, IRPS Bulletin, Report on ISRP 10 student session, 20 (Dec. 2006) 9
R16: C. T. CHANTLER, Australian Physics 45 (2008, ISSN 1036-3831) 66
R17: C. T .CHANTLER, IRPS Bulletin, Members memories of John Hubbell, 21 (2007) p11
R18: C. T .CHANTLER, IRPS Bulletin, Vice-President Report, (2008)
R19: C. T. CHANTLER, IRPS Bulletin, Programme of International Forum on Future Directions in Atomic and Condensed Matter Research and Applications,
22 (Oct. 2008) pp8-20
R20: C. T .CHANTLER, IRPS Bulletin, Profile of Member, 22 (Dec 2008) p8
R21: C. T. CHANTLER, IRPS Bulletin, Report on International Forum on Future Directions in Atomic and Condensed Matter Research and Applications,
23 (April 2009) pp15-16
Thesis & pre-thesis work:
Chris. Chantler, chantler@unimelb.edu.au NIST Database Publication:
Selected Refereed Conference Proceedings:
Miscellaneous Reports:
Last modified: Nov 2015
Copyright © 2015 The University of Melbourne